The following is a list of ordering information for the Autoread Plus system, as well as all of its available parts and accessories.
| Accessory |
Part Number |
|
QBC Autoread Plus Centrifugal Hematology System
|
428605
|
|
The QBC Autoread Plus is an affordable and durable dry hematology system that can deliver a 9-part Complete Blood Count.
The Autoread Plus system comes with the Autoread Plus tube analyzer, QBC Centrifuge, Brother HL-5340D Printer, parallel printer cable, pipetter, AccuTube starter kit, software cartridge, workstation, calibration rod, and power packs for all equipment, including U.S. and European line cords.
|
|
QBC Autoread Plus Analyzer with Accessories
|
429577
|
|
Replacement Autoread Plus tube analyzer with power pack, U.S. and European line cords, software cartridge, workstation, and AccuTube starter kit.
|
|
QBC Autoread Plus Anazlyzer
|
429576
|
|
Replacement Autoread Plus tube analyzer without accessories.
|
|
QBC Centrifuge
|
425740
|
|
This centrifuge can be used to spin all QBC tubes (except for the STAR Tube) for testing in the Autoread Plus analyzer.
The centrifuge has 20 tube slots, and rotates at 12,000 RPM. Comes with power pack and U.S. and European line cords.
|
|
Brother HL-5340D Printer
|
422932
|
|
This 120V, 50/60Hz laser printer serves as the external printer for use with the Autoread Plus system.
|
|
Parallel Printer Cable
|
424407
|
|
This cable is required to connect the Autoread analyzer to an external printer, such as the Brother HL-5340D.
|
|
QBC AccuTubes (Box of 100)
|
423406
|
|
AccuTubes contain acridine orange dye required to stain blood samples for analysis in the Autoread Plus.
AccuTubes can be used for capillary or venous blood samples using the pipetter.
They are packaged with a ventilated stopper at the end of the tube, and soft grip float holder for easy insertion of the plastic float.
|
|
E-Z Prep Capillary Tubes (Box of 100)
|
424641
|
|
E-Z Prep Tubes are packaged with a ventilated stopper and a pre-inserted float within the tube.
Also includes a plastic stylus to ensure proper float placement.
|
|
QBC Venous Tubes (Box of 100)
|
424240
|
|
QBC Venous Tubes (Box of 1000)
|
424237
|
|
These tubes can be used with the pipetter to draw samples from venous tubes.
Contains individual trays of 10 tubes with external floats and manual closures.
|
|
QBC Capillary Tubes (Box of 100)
|
424241
|
|
QBC Capillary Tubes (Box of 1000)
|
424238
|
|
These tubes can be used with blood samples taken from a finger or heel stick.
Contains individual trays of 10 tubes with external floats and manual closures.
|
|
1.8mm Blade Lancets (Box of 100)
|
420000
|
|
2.3mm Blade Lancets (Box of 100)
|
420001
|
|
These spring loaded lancets are ideal for drawing blood for use with QBC Tubes.
The 1.8mm version is designed for pediatric use, while the 2.3mm blade lancets are designed for use on adults.
|
|
Hematology Controls (U.S. Only)
|
424304
|
|
These control samples are designed to test abnormal blood cell count values, and are a necessity for domestic customers to meet CLIA requirements for the Autoread Plus.
The controls are shipped every three weeks, and contain 6 vials each of two different blood samples.
|
|
Calibration Check Rod
|
424613
|
|
This specially coded metal carrier rod is used to calibrate the Autoread Plus system.
|
|
Work Station
|
424226
|
|
Sturdy plastic workstation that can be used to hold 100 tubes of varying sizes, including QBC Tubes.
|
|
QBC Pipetter
|
424225
|
|
This replacement pipetter is used with the AccuTube or QBC Venous Tube to draw the correct amount of blood into the tube for testing.
Includes AccuTube Pipetter Spacer.
|
|
Pipetter Barrel
|
421705
|
|
Replacement barrel (the portion of the pipetter into which tubes are inserted) for the pipetter.
|
|
AccuTube Pipetter Spacer
|
421706
|
|
This spacer is attached to the pipetter to draw the correct amount of blood into the AccuTube during venous tests.
|
|
Autoread Plus System Operator's Manual
|
424593
|
|
A replacement copy of the Autoread Plus manual.
|
|
QBC Autoread Plus Analyzer Software Cartridge
|
429407
|
|
This replacement cartridge serves as the central processing unit for the Autoread Plus tube analyzer.
It can be plugged into an Autoread Plus analyzer with a broken or defective software cartridge.
This replacement cartridge serves as the central processing unit for the Autoread Plus tube analyzer.
It can be plugged into an Autoread Plus analyzer with a broken or defective software cartridge.
|
|
QBC Autoread Plus Analyzer Power Pack
|
424590
|
|
Replacement power pack for the Autoread Plus tube analyzer, which can be used with any QBC line cord.
|
|
QBC Centrifuge Power Pack
|
421763
|
|
Replacement power pack for the QBC Centrifuge, which can be used with any QBC line cord.
|
|
Line Cord (USA)
|
421634
|
|
Line Cord (U.K.)
|
421554
|
|
Line Cord (Europe)
|
421551
|
|
Replacement line cords are available for the Autoread Plus tube analyzer and Centrifuge in the United States, the United Kingdom, and Europe.
|
|
QBC Centrifuge Cover Assembly
|
421291
|
|
Replacement cover for the inside of the QBC Centrifuge.
Contains both the metal disc cover and the rotor cover access knob.
|
|
QBC Rotor Cover Access
|
421317
|
|
Replacement rotor cover access knob for the inside of the QBC Centrifuge.
Contains only the rotor cover access knob.
|